better hysteresis temperature control implementation
This commit is contained in:
@@ -708,7 +708,9 @@ class EnclosurePlugin(octoprint.plugin.StartupPlugin,
|
||||
linked_data = self.get_linked_temp_sensor_data(
|
||||
linked_id)
|
||||
|
||||
if str(temp_hum_control['temp_ctr_type']) == 'dehumidifier':
|
||||
control_type = str(temp_hum_control['temp_ctr_type'])
|
||||
|
||||
if control_type == 'dehumidifier':
|
||||
current_value = self.to_float(linked_data['humidity'])
|
||||
temp_deadband = 0
|
||||
else:
|
||||
@@ -717,15 +719,15 @@ class EnclosurePlugin(octoprint.plugin.StartupPlugin,
|
||||
|
||||
if set_temperature - temp_deadband > current_value:
|
||||
current_status = True
|
||||
elif set_temperature + temp_deadband < current_value:
|
||||
elif set_temperature < current_value:
|
||||
current_status = False
|
||||
else:
|
||||
current_status = previous_status
|
||||
|
||||
if str(temp_hum_control['temp_ctr_type']) == 'cooler' or str(temp_hum_control['temp_ctr_type']) == 'dehumidifier':
|
||||
if control_type == 'cooler' or control_type == 'dehumidifier':
|
||||
current_status = not current_status
|
||||
|
||||
if temp_hum_control['temp_ctr_type'] == 'heater' and max_temp > 0.0 and max_temp < current_value:
|
||||
if control_type == 'heater' and max_temp > 0.0 and max_temp < current_value:
|
||||
if self._settings.get(["debug"]) is True:
|
||||
self._logger.info(
|
||||
"Maximun temperature reached for temperature control %s", temp_hum_control['index_id'])
|
||||
|
||||
Reference in New Issue