<h2><b>spectro/dispread</b>&nbsp;</h2>
<h3>Summary</h3>
Display test patches on a monitor, read the colorimetric value
result with the colorimeter, and create the chart readings file. The
type of instrument is determined by the communication port selected.
Emission and display measurement instruments are supported.<br>
<br>
If you want to read a display manually rather than automatically,
see <a href="chartread.html">chartread</a> and the <a
href="chartread.html#d">-d</a> option.<br>
<h3>Usage</h3>
<small style="font-family: monospace;">dispread [-options]<i>
inoutfile</i><br>
&nbsp;<a href="#v">-v</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
&nbsp;&nbsp;&nbsp;&nbsp; Verbose mode<br>
&nbsp;</small><font size="-1"><a style="font-family: monospace;"
href="#display">-display displayname</a><span
style="font-family: monospace;"> [X11 only] Choose X11 display
name<br>
</span></font><font size="-1"><span style="font-family:
monospace;">&nbsp;<a href="#dnm">-d n[,m]</a>
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
[X11 only]Choose the display from the following list (default
1),<br>
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
and
optionally
choose
a
different
display
m
for VideoLUT access.</span></font><br>
<font size="-1"><span style="font-family: monospace;">&nbsp;<a
href="#d">-d n</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Choose
the
display
from
the
following
list
(default 1)</span></font><small style="font-family: monospace;"><br>
</small><span style="font-family: monospace;">&nbsp;<a href="#dweb">-d
web[:port]</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Display
via a web server at port (default 8080)</span><br>
<span style="font-family: monospace;">&nbsp;<tt><a href="#dcc">-d
cc[:n]</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
</tt><tt>Display via n'th ChromeCast (default 1, ? for list)<br>
</tt></span>&nbsp; <span style="font-family: monospace;"><a
href="#dmadvr">-d madvr</a>
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
[MSWin] Display via MadVR Video Renderer</span><br>
<span style="font-family: monospace;"><span style="font-family:
monospace;">&nbsp;<span style="font-family: monospace;"><a
href="#dummy">-d dummy</a>
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Dummy (non-existant, invisible) display<br>
</span></span></span><small style="font-family: monospace;"><span
style="font-family: monospace;">&nbsp;</span><a
style="font-family: monospace;" href="#c">-c listno</a><span
style="font-family: monospace;"> &nbsp; &nbsp;
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Set communication port from
the following list (default 1)<br>
</span></small><font size="-1"><span style="font-family:
monospace;">&nbsp;<a href="#p">-p</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Use telephoto mode (ie. for a projector, if available)<br>
</span></font><font size="-1"><span style="font-family:
monospace;"><font size="-1"><span style="font-family:
monospace;">&nbsp;<a href="#a">-a</a>
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Use ambient mode (ie. for a projector, if available)</span></font><br>
</span></font> &nbsp; <font size="-1"><span style="font-family:
monospace;"><a href="#y">-y X</a>
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Display
type - instrument specific list to choose from.</span></font><br>
<small style="font-family: monospace;">&nbsp;<span
style="text-decoration: underline;">-</span><a href="#k">k
file.cal</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Load calibration file into display while reading<br>
</small><small style="font-family: monospace;">&nbsp;<span
style="text-decoration: underline;">-</span><a href="#K">K
file.cal</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Apply
calibration file to test values while reading</small><br>
<tt>&nbsp;<a href="#V">-V</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
[MSWin] Enable MadVR color management (3dLut)</tt><br>
<small style="font-family: monospace;">&nbsp;<a href="#s">-s</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
&nbsp;&nbsp;&nbsp;&nbsp; Save spectral information (default don't
save)<br>
</small><font style="font-family: monospace;" size="-1">&nbsp;<a
href="#P">-P ho,vo,ss[,vs]</a>&nbsp;&nbsp;&nbsp;&nbsp; Position
test window and scale it<br>
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
ho,vi:
0.0
=
left/top,
0.5
=
center,
1.0 = right/bottom etc.<br>
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
ss:
0.5
=
half,
1.0
=
normal,
2.0 = double etc.<br>
</font><font size="-1"><span style="font-family: monospace;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
ss,vs: = optional horizontal, vertical scale.</span></font><br>
<font style="font-family: monospace;" size="-1"> &nbsp;</font><font
size="-1"><span style="font-family: monospace;"><a href="#F">-F</a>
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Fill whole screen with black background</span></font><br>
<font size="-1"><span style="font-family: monospace;">&nbsp;</span></font><font
size="-1"><span style="font-family: monospace;"><a href="#E">-E</a>
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
</span></font><small><span style="font-family: monospace;">Video
encode output as (16-235)/255 "TV" levels</span></small><br>
<font size="-1"><span style="font-family: monospace;">&nbsp;</span></font><font
size="-1"><span style="font-family: monospace;"><a href="#Z">-Z
nbits</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
</span></font><small><span style="font-family: monospace;">Quantize
test
values
to
fit
in nbits</span></small><br style="font-family: monospace;">
<small style="font-family: monospace;">&nbsp;<span
style="text-decoration: underline;"></span><a href="#n">-n</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
&nbsp;&nbsp;&nbsp;&nbsp;
[X11
only]
Don't
set
override
redirect
on test window<br>
</small><small style="font-family: monospace;">&nbsp;<a href="#J">-J</a>
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
&nbsp;&nbsp;&nbsp;&nbsp; Run calibration first (used rarely)</small><br>
<font size="-1"><span style="font-family: monospace;">&nbsp;<a
href="#N">-N</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Disable initial calibration of instrument if possible<br>
&nbsp;<a moz-do-not-send="true" href="#h">-h scale</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Scale instrument calibration patch values (default 1.0)<br>
</span></font><font size="-1"><span style="font-family:
monospace;">&nbsp;</span><a style="font-family: monospace;"
href="#H">-H</a><span style="font-family: monospace;">
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
&nbsp;&nbsp;&nbsp;&nbsp; Use high resolution spectrum mode (if
available)</span></font><font size="-1"><span
style="font-family: monospace;"></span><span style="font-family:
monospace;"><br>
&nbsp;<a href="#w">-w</a>
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Disable
normalisation
of
white
to
Y
=
100</span></font><small><span style="font-family: monospace;"></span></small><br>
&nbsp; <font size="-1"><span style="font-family: monospace;"><a
href="#X1">-X file.ccmx</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Apply Colorimeter Correction Matrix</span></font><br>
<span style="font-family: monospace;">&nbsp;<a href="#X2">-X
file.ccss</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Use
Colorimeter
Calibration
Spectral Samples for calibration</span><font size="-1"><span
style="font-family: monospace;"><br>
</span></font><small><span style="font-family: monospace;">&nbsp;</span><a
style="font-family: monospace;" href="#Q">-Q <i>observ</i></a><span
style="font-family: monospace;">&nbsp; &nbsp; &nbsp; &nbsp;
&nbsp;&nbsp;&nbsp; Choose CIE Observer for spectrometer or CCSS
colorimeter data:</span><br style="font-family: monospace;">
<span style="font-family: monospace;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 1931_2 </span></small><small><span
style="font-family: monospace;">(def.)</span></small><small><span
style="font-family: monospace;">, 1964_10, </span></small><small><span
style="font-family: monospace;"><tt><small>2015_2, 2015_10, </small></tt>S&amp;B
1955_2, shaw, J&amp;V 1978_2, 1964_10c or file.cmf</span></small><br>
<small><span style="font-family: monospace;">&nbsp;<a
href="dispread.html#I">-I b|w</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Drift
compensation,
Black:
-Ib,
White:
-Iw,
Both:
-Ibw</span></small><br>
<small><span style="font-family: monospace;"><tt>&nbsp;<a href="#YR">-Y
R:<i>rate</i></a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Override measured refresh rate with rate Hz<br>
</tt>&nbsp;</span></small><font size="-1"><span
style="font-family: monospace;"></span><a style=" font-family:
monospace;" href="#YA">-<font size="-1">Y</font> A</a><span
style="font-family: monospace;">
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Use non-adaptive integration time mode (if available).</span></font><br>
<font size="-1"><span style="font-family: monospace;">&nbsp;</span><a
style=" font-family: monospace;" href="#Yp">-<font size="-1">Y</font>
<font size="-1">p</font></a><span style="font-family:
monospace;">
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
&nbsp;&nbsp;&nbsp; Don't wait for the instrument to be placed on
the display<br>
</span></font><font size="-1"><span style="font-family:
monospace;"><font size="-1"><span style="font-family:
monospace;">&nbsp;</span><a style=" font-family: monospace;"
href="#Yk">-<font size="-1">Y</font> k</a><span
style="font-family: monospace;">
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
&nbsp;&nbsp;&nbsp; Omit the file.cal information from the
.ti3 file</span></font><br>
</span></font> <font size="-1"><span style="font-family:
monospace;">&nbsp;</span><a style="font-family: monospace;"
href="#C">-C "command"</a><span style="font-family: monospace;">
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Invoke shell
"command" each time a color is set<br>
</span></font><font size="-1"><span style="font-family:
monospace;">&nbsp;</span><a style="font-family: monospace;"
href="#M">-M "command"</a><span style="font-family: monospace;">
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Invoke shell
"command" each time a color is measured</span></font><br>
<small>&nbsp; <a style="font-family: monospace;" href="#x">-x x</a><span
style="font-family: monospace;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Take
manually entered XYZ values</span></small><br>
<font size="-1"><span style="font-family: monospace;">&nbsp;<a
href="#W">-W n|h|x</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Override
serial
port
flow
control:
n
=
none, h = HW, x = Xon/Xoff</span></font><br>
<small style="font-family: monospace;">&nbsp;<a href="#D">-D [level]</a>
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Print debug
diagnostics to stderr</small><br>
<small style="font-family: monospace;">&nbsp;<a href="#p1"><i>inoutfile</i></a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Base name for input[<a href="File_Formats.html#.ti1">.ti1</a>]/output[<a
href="File_Formats.html#.ti3">.ti3</a>] file.<br>
</small> <br>
<b>Examples</b><br>
<br>
dispread mydisplay<br>
<h3>Comments<br>
</h3>
This is the tool for exercising a display, in order to measure its
color characteristics. The device test colors are defined by the
outfile.ti1 file, while the resulting device+colorimetric and
optional spectral readings are stored in the outfile.ti3 file.
Display calibration curves can be applied during the measurements,
and the curves included in the resulting .ti3 data file using the <span
style="font-weight: bold;">-k</span>flag. See <a
href="dispcal.html">dispcal</a> for information on how&nbsp; to
calibrate the display before profiling it. For best results, you
should run this against a neutral grey desktop background, and avoid
having any bright images or windows on the screen at the time you
run it.<br>
<br>
<a name="v"></a> The <b>-v</b> flag reports progress information.<br>
<br>
<a name="display"></a><span style="font-weight: bold;">-display</span>:
When running on a UNIX based system that used the X11 Windowing
System, <b>dispread</b> will by default use the $DISPLAY
environment variable to determine which display and screen to read
from. This can be overridden by supplying an X11 display name to the
<span style="font-weight: bold;">-display</span> option. Note that
if Xinerama is active, you can't select the screen using $DISPLAY or
-display, you have to select it using the <span style="font-weight:
bold;">-d</span> parameter.<br>
<br>
<a name="d"></a> <span style="font-weight: bold;">-d</span>: By
default the main display will be the location of the test window. If
the system has more than one display or screen, an alternate
display/screen can be selected with the <span style="font-weight:
bold;">-d</span> parameter. If you invoke <span
style="font-weight: bold;">dispread</span> so as to display the
usage information (i.e. "dispread -?" or "dispread --"), then the
discovered displays/screens will be listed. Multiple displays may
not be listed, if they appear as a single display to the operating
system (ie. the multi-display support is hidden in the video card
driver). On UNIX based system that used the X11 Windowing System,
the <span style="font-weight: bold;">-d</span> parameter will
override the screen specified by the $DISPLAY or <span
style="font-weight: bold;">-display</span> parameter.<br>
<br>
On X11 the inability to access VideoLUTs could be because you are
trying to access a remote display, and the remote display doesn't
support the XF86VidMode extension, or perhaps you are running
multiple monitors using NVidia TwinView, or MergedFB, and trying to
access anything other than the primary monitor. TwinView and
MergedFB don't properly support the XF86VidMode extension for
multiple displays. You can use <a href="dispwin.html#r">dispwin -r</a>
to test whether the VideoLUTs are accessible for a particular
display. See also below, on how to select a different display for
VideoLUT access. Also note that dispcal will fail if the Visual
depth doesn't match the VideoLUT depth. Typically the VideoLUTs have
256 entries per color component, so the Visual generally needs to be
24 bits, 8 bits per color component.<br>
<br>
<a name="dnm"></a>Because of the difficulty cause by TwinView and
MergedFB in X11 based systems, you can optionally specify a separate
display number after the display that is going to be used to present
test patches, for accessing the VideoLUT hardware. This must be
specified as a single string, e.g. <span style="font-weight: bold;">-d
1,2</span> . Some experimentation may be needed using <a
href="dispwin.html">dispwin</a> on such systems, to discover what
screen has access to the VideoLUT hardware, and which screens the
test patches appear on. You may be able to calibrate one screen, and
then share the calibration with another screen. Profiling can be
done independently to calibration.<br>
<br>
<a name="dweb"></a><span style="font-weight: bold;">-dweb</span> or
<span style="font-weight: bold;">-dweb:port</span> starts a
standalone web server on your machine, which then allows a local or
remote web browser to display the the color test patches. By default
port <span style="font-weight: bold;">8080</span> is used, but this
can be overridden by appending a <span style="font-weight: bold;">:</span>
and the port number i.e. <span style="font-weight: bold;">-dweb:8001</span>.
The URL will be <span style="font-weight: bold;">http://</span>
then name of the machine or its I.P. address followed by a colon and
the port number - e.g something like <span style="font-weight:
bold;">http://192.168.0.1:8080</span>. If you use the verbose
option (<span style="font-weight: bold;">-v</span>) then a likely
URL will be printed once the server is started, or you could run <span
style="font-weight: bold;">ipconfig</span> (MSWin) or <span
style="font-weight: bold;">/sbin/ifconfig</span> (Linux or OS X)
and identify an internet address for your machine that way. <b>
JavaScript</b> needs to be enabled in your web browser for this to
work. You may have to modify any firewall to permit port 8080 to be
accessed on your machine.<br>
<br>
Note that if you use this method of displaying test patches, that
there is no access to the display VideoLUTs and that the colors will
be displayed with 8 bit per component precision, and any
screen-saver or power-saver will not be disabled. You will also be
at the mercy of any color management applied by the web browser, and
may have to carefully review and configure such color management.
See the <a href="dispcal.html#o">-o</a> flag for an explanation of
the implications of having no access to the VideoLUTs.<br>
<br>
<a name="dcc"></a><span style="font-weight: bold;">-dcc</span> or <b>-dcc:<i>no</i></b>
causes test patches to be displayed using and available <a
href="http://en.wikipedia.org/wiki/Chromecast">ChromeCast</a> to
your TV. Use <b>-dcc:?</b> to display a list of ChromeCasts on your
local network. Note that the ChromeCast as a test patch source is
probably the<b> least accurate</b> of your choices, since it
up-samples the test patch and transforms from RGB to YCC and back,
but should be accurate within 1 bit. You may have to modify any
firewall to permit port 8081 to be accessed on your machine if it
falls back to the Default receiver (see <a href="Installing.html">installation
instructions</a> for your platform).<br>
<br>
<a name="dmadvr"></a><span style="font-weight: bold;">-dmadvr</span>
[MSWin only] causes test patches to be displayed using the MadVR
video renderer. Note that will have to start <b>MadTPG</b> before
running dispread, and that while you can adjust the "Test Pattern
Configuration" controls, you should <u>not</u> normally alter the
"Existing Calibration" controls, as dispread will set these
appropriately. See also <tt><a href="#V">-V</a> flag.<br>
</tt><br>
<a name="dummy"></a><span style="font-weight: bold;">-ddummy</span>
causes test patches not to be displayed at all. This is useful when
used with the these appropriately. This is useful when patch values
are going to be displayed via the <a href="#C">-<span
style="font-weight: bold;">C</span></a><span style="font-weight:
bold;"> </span>option.<br>
<tt> </tt> <br>
<a name="c"></a> <span style="font-weight: bold;">-c</span>: The
instrument is assumed to communicate through a USB or serial
communication port, and the port can be selected with the <b>-c</b>
option, if the instrument is not connected to the first port. If you
invoke <span style="font-weight: bold;">dispread</span> so as to
display the usage information (i.e. "dispread -?" or "dispread --"),
then the discovered USB and serial ports will be listed. On
UNIX/Linux, a list of all possible serial ports are shown, but not
all of them may actually be present on your system.<br>
<br>
<a name="p"></a>The <span style="font-weight: bold;">-p</span> flag
allows measuring in telephoto mode, using instruments that support
this mode, e.g. the ColorMunki. Telephoto mode is one for taking
emissive measurements from a distance (ie. telespectometer,
tele-colorimeter) mode, and typically would be used for measuring
projector type displays. If a device does not support a specific
telephoto mode, then the normal emissive mode may be suitable for
measuring projectors.<br>
<br>
<a name="a"></a>The <span style="font-weight: bold;">-a</span> flag
allows measuring in ambient mode, using instruments that support
this mode. This typically would be used for measuring projector type
displays when the light levels reflected from the projection surface
are very low. Note that this means that the color value will not be
quite as accurate, because the effect the projection surface has on
the color is not taken into account.<br>
<br>
<a name="y"></a>The <span style="font-weight: bold;">-y</span> flag
allows setting the Display Type. The selection typically determines
two aspects of of the instrument operation: <span
style="font-weight: bold;">1)</span> It may set the measuring mode
to suite <a
href="http://en.wikipedia.org/wiki/Comparison_of_display_technology"><span
style="font-weight: bold;">refresh</span> or <span
style="font-weight: bold;">non-refresh</span> displays</a>.
Typically only LCD (Liquid Crystal) displays have a non-refresh
nature. <span style="font-weight: bold;">2)</span> It may select an
instrument calibration matrix suitable for a particular display
type. The selections available depends on the type and model of
instrument, and a list of the options for the discovered instruments
will be shown in the <a href="ArgyllDoc.html#CmdLine">usage</a>
information. For more details on what particular instruments support
and how this works, see <a href="instruments.html">Operation of
particular instruments</a>. <b>3)</b> Any installed CCSS files
(if applicable), or CCMX files. These files are typically created
using <a href="ccxxmake.html">ccxxmake</a>, and installed using <a
href="oeminst.html">oeminst</a>. The default and Base Calibration
types will be indicated in the usage.<br>
<br>
<a name="s"></a><span style="font-weight: bold;">-s</span>: By
default only the colorimetric information (XYZ value) will be saved,
but for instruments that support spectral readings (such as the
Gretag Spectrolino), the <b>-s</b> option will save the spectral
readings to the .ti3 file as well.<br>
<br>
<a name="k"></a> <span style="font-weight: bold;">-k: </span>If a
display video lookup table calibration <a
href="File_Formats.html#.cal">.cal</a> file is provided, it will
be loaded into the display <span style="font-weight: bold;">VideoLUTs</span>
while the measurements are being taken, thereby being applied to the
measurement values, and the calibration will also included in the
resulting .ti3 data file, so that <a href="colprof.html">colprof</a>
can include it as a <span style="font-weight: bold;">vcgt</span>
tag in the resulting profile. This is the <span style="font-weight:
bold;">normal</span> way to profile a calibrated display. The
calibration file has usually been created using <a
href="dispcal.html">dispcal</a>. If the calibration file indicates
that the displays VideoLUTs are not accessible, or if they prove not
to be accessible, then dispread will switch to <span
style="font-weight: bold;">-K</span> mode (see below). If a
calibration file is not supplied using <b>-k</b> or <b>-K</b>,
then the display will be measured in whatever calibration state it
is in, and no calibration information is saved to the resulting .ti3
file.<br>
If the calibration file provided created using video range encoding
(dispcal -E), then the <b>-E</b> option in dispread will be
triggered automatically.<br>
<span style="font-weight: bold;">NOTE</span> that the calibration is
loaded into the display hardware just before the instrument starts
measurement, after the test window first appears.<br>
See also the <a href="#Yk">-Y k</a> flag.<br>
<br>
<a name="K"></a> <span style="font-weight: bold;">-K: </span>If a
display video lookup table calibration <a
href="File_Formats.html#.cal">.cal</a> file is provided, it will
be applied to the test values for each measurement, and also
included in the resulting .ti3 data file, so that <a
href="colprof.html">colprof</a> can include it as a <span
style="font-weight: bold;">vcgt</span> tag in the resulting
profile. This is <span style="font-weight: bold;">NOT</span>
normally the best way to profile a calibrated display, since the
frame buffer may have lower precision than the VideoLUTs output
values. This is the way calibration should be applied if MadVR is
being used to display the test patches. If a calibration file is not
supplied using <b>-k</b> or <b>-K</b>, then the display will be
measured in whatever calibration state it is in, and no calibration
information is saved to the resulting .ti3 file.<br>
If the calibration file provided created using video range encoding
(dispcal -E), then the <b>-E</b> option in dispread will be
triggered automatically.<br>
See also the <a href="#Yk">-Y k</a> flag.<br>
<br>
<a name="V"></a><b>-V:</b> [MSWin] If using MadVR to display test
patches, then enable Color Managenent (3dLut). This would be used
for verification measurement.<br>
<br>
<a name="P"></a> The <span style="font-weight: bold;">-P</span>
parameter allows you to position and size the test patch window. By
default it is places in the center of the screen, and sized
appropriately for the type of instrument, or 10% of the width of the
display if the display size is unknown. The <span
style="font-weight: bold;">ho</span> and <span
style="font-weight: bold;">vo</span> values govern the horizontal
and vertical offset respectively. A value of 0.0 positions the
window to the far left or top of the screen, a value of 0.5
positions it in the center of the screen (the default), and 1.0
positions it to the far right or bottom of the screen. If three
parameters are provided, then the <span style="font-weight: bold;">ss</span>
parameter is a scale factor for the test window size. A value of 0.5
for instance, would produce a half sized window. A value of 2.0 will
produce a double size window. If four parameters are provided, then
the last two set independent horizontal and vertical scaling
factors. Note that the ho,vo,ss or ho,vo,hs,vs numbers must be
specified as a single string (no space between the numbers and the
comma). For example, to create a double sized test window at the top
right of the screen, use <span style="font-weight: bold;">-P 1,0,2</span>
. To create a window twice as wide as high: <span
style="font-weight: bold;">-P 1,0,2,1</span>.<br>
<br>
<a name="F"></a> The <span style="font-weight: bold;">-F</span>
flag causes the while screen behind the test window to be masked
with black. This can aid black accuracy when measuring CRT displays
or projectors.<br>
<br>
<a name="E"></a> The <span style="font-weight: bold;">-E</span>
flag causes the test values to be scaled to the Video RGB encoding
range of 16/255 to 235/255. If the calibration file provided using
the <b>-k</b> or <b>-K</b> flag was created using video range
encoding, then this option will be triggered automatically. This
will also set quantization of 8 bits (see -Z flag below). If your
frame buffer and video connection is better than 8 bits (ie. 10 or
12 bits), then you may wish to raise this default.<br>
<br>
<a name="Z"></a> <b>-Z nbits </b>Normally the target device values
are floating point numbers that may get rounded and quantized in the
process of printing them or reproducing them on the display device.
If some of this quantization can be accounted for, it may improve
the accuracy of the resulting profile, and the <span
style="font-weight: bold;">Z</span> parameter allows this
quantization to be specified. The parameter is the number of binary
digits (bits) that the device values should be quantized to. This
will depend on the frame buffer depth that dispread has access to,
and for MSWindows and Apple OS X this is typically 8 bits, while X11
systems may have access to a deeper frame buffer. If Video encoding
is selected (see -E flag above), then 8 bits is selected by default.
On systems using a VGA connection or Display Port with a deeper than
8 bit frame buffer and similar path to the display, or if using the
MadVR rendered with dithering, then a higher bit depth is typically
possible.<br>
<br>
Often it is hard to notice any practical difference whether this
option is used or not, since the repeatability of displays and
measurement instruments can often exceed the extra precision of 8
bits per color component. The benefits of extra frame buffer
precision are mainly in the areas of better smoothness for
gradients, particularly using wide gamut or HDR displays, while
sampling of color spaces for the purposes of profiling is typically
sparse due to limitations of measurement speed.<br>
<br>
<a name="n"></a><span style="font-weight: bold;">-n</span>: When
running on a UNIX based system that used the X11 Windowing System, <b>dispread</b>
normally selects the override redirect so that the test window will
appear above any other windows on the display. On some systems this
can interfere with window manager operation, and the <b>-n</b>
option turns this behaviour off.<br>
<br>
<a name="J"></a> The -<span style="font-weight: bold;">J</span>
option runs through the black and sensor relative calibration
routines for the Xrite DTP92 and DTP94 instrument, the black level
calibration for the Eye-One Display 1, and a CRT frequency
calibration for the Eye-One Display 2. For the black calibration the
instrument should be placed on an opaque, black surface, and any
stray light should be avoided by placing something opaque over the
instrument. If a Spectrolino is being used, then a white and black
calibration will always be performed before the instrument can be
placed on the display, unless the <a href="#N">-N</a> flag is used.
Generally it is not necessary to do a calibration every time an
instrument is used, just now and again. There is no point in
doing&nbsp; a CRT frequency calibration, as this will be done
automatically at the commencement of patch reading.<br>
<br>
<a name="N"></a> <span style="font-weight: bold;">-N</span> Any
instrument that requires regular calibration will ask for
calibration on initial start-up. Sometimes this can be awkward if
the instrument is being mounted in some sort of measuring jig, or
annoying if several sets of readings are being taken in quick
succession. The -<span style="font-weight: bold;">N</span>
suppresses this initial calibration if a valid and not timed out
previous calibration is recorded in the instrument or on the host
computer. It is advisable to only use this option on the second and
subsequent measurements in a single session.<br>
<br>
<a name="h"></a> <span style="font-weight: bold;">-h <i>scale</i></span>
Often there are automatic display instrument calibrations, such as
measuring the time between changing a patch color and the instrument
registering it, measuring the refresh rate, or calibrating the
instrument. These calibrations use pre-set patch values that may not
be ideal for HDR displays, so the <b>-h <i>scale</i></b> parameter
allows scaling these values down. A value less than 1.0 would
typically be provided. This value does not affect the .ti1 test
patch values.<br>
<br>
<a name="H"></a> The -<span style="font-weight: bold;">H</span>
option turns on high resolution spectral mode, if the instrument
supports it. See <a href="instruments.html">Operation of particular
instruments</a> for more details. This may give better accuracy
for display measurements.<br>
<br>
<a name="w"></a>The <b>-w</b> flag disables the normalisation of
the white patch value to 100.0, resulting in values that are in
cd/m^2. This is mainly for diagnostic purposes. By default dispread
will add a white patch if the .ti1 file doesn't contain one, so that
the .ti3 values can be normalized to 100.0, but this is not done if
the <b>-w</b> flag is used. If <b>-w</b> is used and the .ti1 file
doesn't contain a white patch, then the brightness of the display
will not be recorded in the resulting .ti3 file
(LUMINANCE_XYZ_CDM2).<br>
<br>
<a name="X1"></a> The -<span style="font-weight: bold;">X <span
style="font-style: italic;">file.ccmx</span></span> option reads
a <a href="File_Formats.html#.ccmx">Colorimeter Correction Matrix</a>
from the given file, and applies it to the colorimeter instruments
readings. This can improve a colorimeters accuracy for a particular
type of display. A list of contributed <span style="font-weight:
bold;">ccmx</span> files is <a href="ccmxs.html">here</a>.<br>
<br>
<a name="X2"></a> The -<span style="font-weight: bold;">X <span
style="font-style: italic;">file.ccss</span></span> option reads
a <a href="File_Formats.html#.ccss">Colorimeter Calibration
Spectral Sample</a> from the given file, and uses it to set the
colorimeter instruments calibration. This will only work with
colorimeters that rely on sensor spectral sensitivity calibration
information (ie. the X-Rite <span style="font-weight: bold;">i1d3</span>,
or the DataColor <span style="font-weight: bold;">Spyder4 &amp;
Spyder 5</span>).This can improve a colorimeters accuracy for a
particular type of display. A list of contributed <span
style="font-weight: bold;">ccss</span> files is <a
href="ccsss.html">here</a>.<br>
<br>
<a name="Q"></a> The <b>-Q</b> flag allows specifying a tristimulus
observer, and is used to compute PCS (Profile Connection Space)
tristimulus values from spectral readings or using a colorimeter
that has CCSS capability. The following choices are available:<br>
<b>&nbsp; 1931_2</b> selects the standard CIE 1931 2 degree
observer. The default.<br>
&nbsp; <b>1964_10</b> selects the standard CIE 1964 10 degree
observer.<br>
<b>&nbsp; 2015_2</b> selects the standard CIE 2015 2 degree observer<br>
&nbsp; <b>2015_10</b> selects the standard CIE 2015 10 degree
observer<br>
&nbsp; <b>1955_2</b> selects the Stiles and Birch 1955 2 degree
observer<br>
&nbsp; <b>1978_2 </b>selects the Judd and Voss 1978 2 degree
observer<br>
&nbsp; <b>shaw</b> selects the Shaw and Fairchild 1997 2 degree
observer<br>
&nbsp; <b>1964_10c</b> selects a version of the CIE 1964 10 degree
observer that has been adjusted using a 3x3 matrix to better agree
with the 1931 2 degree observer.<br>
&nbsp;&nbsp; <i><b>file.cmf</b></i> selects an observer specified
by the given <a href="File_Formats.html#.cmf">.cmf</a> file.<br>
<br>
<span style="font-weight: bold;">NOTE</span> that if you select
anything other than the default 1931 2 degree observer, that the Y
values will not be cd/m^2, due to the Y curve not being the CIE 1924
photopic V(&#955;) luminosity function.<br>
<br>
<a name="I"></a>The -<span style="font-weight: bold;">I <span
style="font-style: italic;">b|w</span></span> options invoke
instrument black level, and display white level compensation
(respectively). Instrument black level drift compensation attempts
to combat instrument black calibration drift by using an initial
display black test patch as a reference,and then measuring black
patches regularly between other measurements. If an instrument is
not acclimatised sufficiently to the measurement conditions, changes
in temperature can affect the black readings. Display white level
drift compensation attempts to combat changes in display brightness
and white point as it warms up by measuring white patches regularly
between other measurements, and using them to normalise all the
other readings to the final white value. If just instrument black
drift compensation is needed, use <span style="font-weight: bold;">-Ib</span>.
If just display white level compensation is needed, use <span
style="font-weight: bold;">-Iw</span>. If both are needed, use <span
style="font-weight: bold;">-Ibw</span> or <span
style="font-weight: bold;">-Iwb</span>.<br>
<br>
<a name="YR"></a> The -<span style="font-weight: bold;">Y R:<i>rate</i></span>
options overrides calibration of the instrument refresh rate. This
may be useful if the instrument supports this function and the
refresh rate cannot be accurately calibrated from the display
itself.<br>
<span style="font-weight: bold;">&nbsp;<br>
</span><a name="YA"></a> The -<span style="font-weight: bold;">Y A</span>
option uses a non-adaptive integration time emission measurement
mode, if the instrument supports it, such as the Eye-One Pro,
ColorMunki, i1d3 and K10. By default an adaptive integration time
measurement mode will be used for emission measurements, but some
instruments support a fixed integration time mode that can be used
with display devices. This may give faster measurement times, but
may also give less accurate low level readings.<br>
<br>
<a name="Yp"></a> The -<span style="font-weight: bold;">Y p</span>
option skips asking the user to place the instrument on the display.
Normally a grey patch is displayed, and then the user is asked to
confirm that the instrument is in place, so that readings can
commence. This flag disables that check. This may be useful in
automating certain operations.<br>
<br>
<a name="Yk"></a> The -<span style="font-weight: bold;">Y k</span>
option is used, then calibration information is omitted, and the
resulting profile will not have a 'vcgt' tag. Normally when
calibration information is provided using the <a href="#k">-k</a>
or <a href="#K">-K</a> options, this is saved to the resulting .ti3
file so that a profile can be created with a matching 'vcgt'
calibration tag.<br>
<span style="font-weight: bold;"><br>
</span><a name="C"></a> The -<span style="font-weight: bold;">C</span>
<span style="font-weight: bold;">"command" </span>option allows a
method of relaying each test value to some other display than that
on the system running dispread (for instance, a photo frame, PDA
screen etc.), by causing the given command to be invoked to the
shell, with six arguments. The first three arguments are the RGB
test color as integers in the range 0 to 255, the second three
parameters are the RGB test color as floating point numbers in the
range 0.0 to 1.0. The script or tool should relay the given color to
the screen in some manner (e.g. by generating a raster file of the
given color and sending it to the display being profiled), before
returning. Note that a test window will also be created on the
system running dispread.<br>
<br>
<a name="M"></a> The -<span style="font-weight: bold;">M</span> <span
style="font-weight: bold;">"command" </span>option allows a
method of gathering each test value from some external source, such
as an instrument that is not directly supported by Argyll. The given
command is involked to the shell, with six arguments. The first
three arguments are the RGB test color as integers in the range 0 to
255, the second three parameters are the RGB test color as floating
point numbers in the range 0.0 to 1.0. The script or tool should
create a file called <span style="font-weight: bold;">"command.meas</span>"
that contains the XYZ values for the given RGB (or measured from the
test window) in cd/m^2 as three numbers separated by spaces, before
returning. If the command returns a non-zero return value, dispread
will abort. Note that a test window will also be created on the
system running dispread.<br>
<br>
<a name="x"></a> The <b>-x</b> flag causes dispread to expect
values to be manually entered for each reading, rather than using an
instrument to do the measurements.&nbsp; This mode is ideal if your
instrument is not supported by Argyll. XYZ values should be entered.
It is possible to navigate about the test values being measured, so
as to do them in any order, as well as re-do values, in case of any
mistakes.<br>
<br>
<a name="W"></a>The <b>-W</b> <span style="font-weight: bold;">n|h|x</span>
parameter overrides the default serial communications flow control
setting. The value <span style="font-weight: bold;">n</span> turns
all flow control off, <span style="font-weight: bold;">h</span>
sets hardware handshaking, and <span style="font-weight: bold;">x</span>
sets Xon/Xoff handshaking. This commend may be useful in workaround
serial communications issues with some systems and cables. <br>
<br>
<a name="D"></a>The <b>-D</b> flag causes communications and other
instrument diagnostics to be printed to stdout. A level can be set
between 1 .. 9, that may give progressively more verbose
information, depending on the instrument. This can be useful in
tracking down why an instrument can't connect.<br>
<br>
<a name="p1"></a> The final parameter on the command line is the
base filename for the <a href="File_Formats.html#.ti1">.ti1</a>
input file, and the <a href="File_Formats.html#.ti3">.ti3</a>
output file. <b>dispread</b> will add the .ti1 and .ti3 extensions
automatically.<br>
<br>
<span style="font-weight: bold;">NOTE</span> that on an X11 system,
if the environment variable <span style="font-weight: bold;">ARGYLL_IGNORE_XRANDR1_2</span>
is set (ie. set it to "yes"), then the presence of the XRandR 1.2
extension will be ignored, and other extensions such as Xinerama and
XF86VidMode extension will be used. This may be a way to work around
buggy XRandR 1.2 implementations.<br>
<br>
<hr style="width: 100%; height: 2px;"><br>
If a large number of patches is being read, the screensaver on many
systems can interfere with the operation of dispread. It is
therefore advisable in these cases to manually turn off the
screensaver before commencing the measurements.<br>
<br>
If communications break down with a USB connected instrument, you
may have to unplug it, and plug it in again to recover.<br>
<br>
Some systems (Apple OSX in particular) have a special set of user
interface controls ("Universal Access") that allows altering the
display in ways designed to assist visually impaired users, by
increasing contrast etc. This will interfere badly with any attempts
to calibrate or profile such a system, and must be turned off in
order to do so. Note that certain magic keyboard sequences can turn
this on by accident.<br>
<br>
<br>
<br>
</body>
</html>