diff --git a/octoprint_enclosure/novus1050.py b/octoprint_enclosure/novus1050.py deleted file mode 100644 index b479199..0000000 --- a/octoprint_enclosure/novus1050.py +++ /dev/null @@ -1,24 +0,0 @@ -#!/usr/bin/env python3 -import minimalmodbus - -## setup ## - # port name, slave address (in decimal) -novus = minimalmodbus.Instrument('/dev/ttyUSB0', 1) -# for Novus 1050 comms documentation see: -# https://cdn.novusautomation.com/downloads/registers_table_n1050_v11x_a_en.pdf -# rs485 to USB adaptor: USB to RS485 TTL Serial Converter Adapter FTDI interface FT232RL 75176 Module -novus.serial.baudrate = 115200 -REG_ADDR = { - 'Active SP': 0, - 'PV': 1, - 'dppo': 73 -} -## Read decimal point precision setting ## -DP = 3 - novus.read_register(REG_ADDR['dppo'], 0) -#print(f'decimal places: {DP}') -## set up complete ## - -class Novus1050Temp: - def getTemp(self): - temperature = novus.read_register(REG_ADDR['PV'], DP) - return '{0:0.1f}'.format(temperature)